About the project
Work result
We performed a complete ECU recalibration and system deactivation on LIEBHERR machinery equipped with the LIDEC2 control unit.
The main goal was to disable AdBlue (SCR), DPF, and EGR systems while ensuring stable and reliable engine performance under heavy-duty conditions.
Using WinOLS, we modified injection and exhaust-related calibration maps, as well as temperature and load correction tables.
After disabling the AdBlue SCR, DPF filter, and EGR valve, all related diagnostic routines were adjusted to prevent DTC errors or dashboard warnings.
The engine now operates smoothly, maintaining full torque and improved fuel efficiency. All checksums were recalculated, and the final file was tested directly on the machine with excellent results.
If you need AdBlue, DPF, or EGR removal for LIEBHERR or other heavy machinery, we can provide a custom solution tailored to your needs.
P155E-00 4340 6 AdBlue line heater 1 - Critical high output current AWL
P1054-2A 4340 11 AdBlue line heater 1 - Electrical error AWL
P1054-00 4340 5 AdBlue line heater 1 - Open circuit
P1052-00 4340 3 AdBlue line heater 1 - Short circuit to battery high side
P1399-00 516306 3 AdBlue line heater 1 - Short circuit to battery low side
P1053-00 4340 4 AdBlue line heater 1 - Short circuit to ground high side
P139A-00 516307 4 AdBlue line heater 1 - Short circuit to ground low side
P155F-00 4342 6 AdBlue line heater 2 - Critical high output current AWL
P1057-2A 4342 11 AdBlue line heater 2 - Electrical error AWL
P1057-00 4342 5 AdBlue line heater 2 - Open circuit
P1055-00 4342 3 AdBlue line heater 2 - Short circuit to battery high side
P139B-00 516308 3 AdBlue line heater 2 - Short circuit to battery low side
P1056-00 4342 4 AdBlue line heater 2 - Short circuit to ground high side
P139D-00 516309 4 AdBlue line heater 2 - Short circuit to ground low side
P1560-00 5706 6 AdBlue pump heating valve - Critical high output current AWL
P1051-2A 5706 11 AdBlue pump heating valve - Electrical error AWL
P1051-00 5706 5 AdBlue pump heating valve - Open circuit
P1049-00 5706 3 AdBlue pump heating valve - Short circuit to battery high side
P139E-00 516310 3 AdBlue pump heating valve - Short circuit to battery low side
P1050-00 5706 4 AdBlue pump heating valve - Short circuit to ground high side
P139F-00 516311 4 AdBlue pump heating valve - Short circuit to ground low side
P203F-00 3532 17 AdBlue tank - Level low Clean the suction module Refill AdBlue tank
P1065-00 3031 15 AdBlue tank - Overtemperature warning The sensor is working correctly, the measured temperature is higher than a threshold.
P207F-00 3516 17 AdBlue tank - Poor AdBlue quality MIL Indcmnt
P1561-00 3363 6 AdBlue tank heating valve - Critical high output current AWL
P202A-2A 3363 11 AdBlue tank heating valve - Electrical error AWL
P202A-00 3363 5 AdBlue tank heating valve - Open circuit
P202C-00 3363 3 AdBlue tank heating valve - Short circuit to battery high side
P13A0-00 516312 3 AdBlue tank heating valve - Short circuit to battery low side
P202B-00 3363 4 AdBlue tank heating valve - Short circuit to ground high side
P13A1-00 516313 4 AdBlue tank heating valve - Short circuit to ground low side
U1019-00 1761 2 AdBlue tank module - Communication error MIL Indcmnt
P203A-13 1761 3 AdBlue tank(level sensor) - Open circuit MIL Indcmnt
P1066-00 1761 4 AdBlue tank(level sensor) - Short circuit MIL Indcmnt
P203A-21 1761 1 AdBlue tank(level sensor) - Value out of minimum range MIL Indcmnt
P1246-00 3364 11 AdBlue tank(quality sensor) - Optic error MIL Indcmnt Clean diesel exhaust fluid tank and suction module
P206A-22 3364 0 AdBlue tank(quality sensor) - Value out of maximum range MIL Indcmnt
P206A-21 3364 1 AdBlue tank(quality sensor) - Value out of minimum range MIL Indcmnt
P1241-22 3515 3 AdBlue tank(temperature sensor at suction position) - Open circuit
P1245-00 3515 15 AdBlue tank(temperature sensor at suction position) - Overtemperature warning
P1272-00 3515 2 AdBlue tank(temperature sensor at suction position) - Plausibility error
P1244-00 3515 4 AdBlue tank(temperature sensor at suction position) - Short circuit
P1242-21 3515 0 AdBlue tank(temperature sensor at suction position) - Value out of maximum range
P1243-13 3515 1 AdBlue tank(temperature sensor at suction position) - Value out of minimum range
P205A-13 3031 3 AdBlue tank(temperature sensor) - Open circuit
P205B-64 3031 2 AdBlue tank(temperature sensor) - Plausibility error
P1064-00 3031 4 AdBlue tank(temperature sensor) - Short circuit
P205A-22 3031 0 AdBlue tank(temperature sensor) - Value out of maximum range
P205A-21 3031 1 AdBlue tank(temperature sensor) - Value out of minimum range
P137E-00 516281 15 Aftertreatment Protection Power Reduction - Overtemperature
P1005-00 107 11 Air filter - Blocked / Clogged AWL LVL 1
P1281-00 2809 11 Air filter 2 - Blocked / Clogged AWL LVL 1
U1018-00 516099 2 Air filter combi sensor - Communication error AWL LVL 1
P1555-00 516099 31 Air filter combi sensor - Internal temperature error AWL LVL 1
P1557-00 4490 31 Air filter combi sensor(Ambient humidity) - Relative ambient temperature error
P1556-00 354 31 Air filter combi sensor(Ambient humidity) - Specific ambient temperature error
P1558-00 106 11 Air filter combi sensor(Pressure) - Pressure error of Trican sensor AWL LVL 1
P1559-00 172 11 Air filter combi sensor(Temperature) - Temperature error of Trican sensor AWL LVL 1
P1132-00 106 2 Air filter pressure sensor - Plausibility error AWL LVL 1 1270 100
P0106-00 516101 11 Air filter pressure switch - Out of range AWL LVL 1 1270 10
P0108-00 516101 3 Air filter pressure switch - Short circuit to battery AWL LVL 1
P0107-00 516101 4 Air filter pressure switch - Short circuit to ground or open circuit AWL LVL 1
P0105-1C 516101 31 Air filter pressure switch - Supply voltage out of range AWL LVL 1
P1301-00 516102 11 Air filter pressure switch 2 - Out of range AWL LVL 1 1270 10
P12FF-12 516102 3 Air filter pressure switch 2 - Short circuit to battery AWL LVL 1
P12FF-14 516102 4 Air filter pressure switch 2 - Short circuit to ground or open circuit AWL LVL 1
P12FF-1C 516102 31 Air filter pressure switch 2 - Supply voltage out of range AWL LVL 1
P0111-64 172 2 Air filter temperature sensor - Plausibility error
P1564-00 516428 31 Air pressure sensors - Plausibility error
P1170-00 516107 11 Alternator control - Alternator defect at engine stop
P1286-00 516108 11 Alternator control - Alternator defect engine running
P1404-00 516485 11 Alternator control - Alternator is not deactivated when it should
P1172-00 516110 11 Alternator control - Alternator voltage control not able to achieve desired setpoint
P1288-00 516111 11 Alternator control - Blown fuse
P1403-00 516484 11 Alternator control - Oscillating control deviation of alternator voltage
P1287-00 516112 11 Alternator control - Smart alternator error 6350 50
P13A4-00 516321 3 Alternator(deactivation) - Short circuit to battery high side
P13A6-00 516323 4 Alternator(deactivation) - Short circuit to ground high side
P1171-00 516104 3 Alternator(frequency input) - Short circuit to battery
P1210-00 516106 0 Alternator(output voltage) - Critical overvoltage AWL - RSL LVL 2
P1209-00 516106 15 Alternator(output voltage) - Overvoltage warning
P1168-00 516106 4 Alternator(output voltage) - Short circuit to ground or open circuit AWL - RSL LVL 2
P1FD4-1C 516106 31 Alternator(output voltage) - Supply voltage out of range AWL - RSL LVL 2
P2227-64 108 2 Ambient pressure sensor - Plausibility error
P133C-1C 108 31 Ambient pressure sensor - Supply voltage out of range
P0070-13 171 5 Ambient temperature sensor - Open circuit
P0071-64 171 2 Ambient temperature sensor - Plausibility error
P0073-00 171 3 Ambient temperature sensor - Short circuit to battery
P0072-00 171 4 Ambient temperature sensor - Short circuit to ground
P1336-00 171 31 Ambient temperature sensor - Supply voltage out of range
P0234-00 1176 1 Boost pressure - Pressure too high 127 100 Check intake manifold for leakages, check wastegate leakage / is closed
P0299-00 1176 0 Boost pressure - Pressure too low 127 100 Check intake manifold for leakages, check wastegate leakage / is closed
U0121-00 973 2 Brakes - System Controller - Communication error
P0340-64 636 2 Camshaft position - Plausibility error AWL - RSL LVL 2 Check speed sensors for visible defects
P0340-F0 636 14 Camshaft position sensor - Ground error AWL - RSL LVL 2
P0340-13 636 5 Camshaft position sensor - Open circuit AWL - RSL LVL 2
P0343-00 636 3 Camshaft position sensor - Short circuit to battery AWL - RSL LVL 2
P0343-00 636 3 Camshaft position sensor - Short circuit to battery or open circuit AWL - RSL LVL 2
P0342-00 636 4 Camshaft position sensor - Short circuit to ground AWL - RSL LVL 2
P0340-1C 636 31 Camshaft position sensor - Supply voltage out of range AWL - RSL LVL 2
P1027-00 157 0 Common rail - Critical overpressure AWL - RSL LVL 2 - CRS
P1022-00 1239 2 Common rail - Leakage
P1026-00 157 15 Common rail - Overpressure warning.
P1325-00 516117 11 Common rail - PCV opened due to overpressure
P13FE-00 1075 2 Common rail - Plausibility error
P1025-00 516118 11 Common rail - Plausibility error of VCV current AWL - RSL LVL 2
P1024-00 516121 11 Common rail - Pressure remains above the set point AWL - RSL LVL 2 - CRS
P1023-00 516122 11 Common rail - Pressure remains below the set point AWL - RSL LVL 2 - CRS
P1019-00 516123 11 Common rail - Start pressure too low AWL 508 1020 Check high pressure fuel pump
P128A-00 1349 0 Common rail 2 - Critical overpressure AWL - RSL LVL 2 - CRS
P12D6-00 1240 2 Common rail 2 - Leakage
P1289-00 1349 15 Common rail 2 - Overpressure warning
P1326-00 516124 11 Common rail 2 - PCV opened due to overpressure
P12D9-00 516125 11 Common rail 2 - Plausibility error of VCV current AWL - RSL LVL 2 - CRS
P12D8-00 516128 11 Common rail 2 - Pressure remains above the set point AWL - RSL LVL 2 - CRS
P12D7-00 516129 11 Common rail 2 - Pressure remains below the set point AWL - RSL LVL 2 - CRS
P12D3-00 516130 11 Common rail 2 - Start pressure too low AWL 508 1020 Check high pressure fuel pump
P1021-00 516131 11 Common rail pressure sensor - No signal variation AWL - RSL LVL 2 - CRS
P0193-00 157 3 Common rail pressure sensor - Short circuit to battery or open circuit AWL - RSL LVL 2 - CRS
P0192-00 157 4 Common rail pressure sensor - Short circuit to ground AWL - RSL LVL 2 - CRS
P0190-1C 157 31 Common rail pressure sensor - Supply voltage out of range AWL - RSL LVL 2 - CRS
P12D5-00 516133 11 Common rail pressure sensor 2 - No signal variation AWL - RSL LVL 2 - CRS
P01C1-00 1349 3 Common rail pressure sensor 2 - Short circuit to battery or open circuit AWL - RSL LVL 2 - CRS
P01C0-00 1349 4 Common rail pressure sensor 2 - Short circuit to ground AWL - RSL LVL 2 - CRS
P01C0-1C 1349 31 Common rail pressure sensor 2 - Supply voltage out of range AWL - RSL LVL 2 - CRS
P1566-00 516474 6 Configurable machine digital output 1 - Critical high output current AWL
P1378-00 516275 11 Configurable machine digital output 1 - Electrical error
P1149-00 516135 5 Configurable machine digital output 1 - Open circuit
P1147-00 516135 3 Configurable machine digital output 1 - Short circuit to battery high side
P1376-00 516273 3 Configurable machine digital output 1 - Short circuit to battery low side
P1148-00 516135 4 Configurable machine digital output 1 - Short circuit to ground high side
P1377-00 516274 4 Configurable machine digital output 1 - Short circuit to ground low side
P1155-00 516137 5 Configurable machine lamp output 1 - Open circuit
P1153-00 516137 3 Configurable machine lamp output 1 - Short circuit to battery high side
P1382-00 516285 3 Configurable machine lamp output 1 - Short circuit to battery low side
P1154-00 516137 4 Configurable machine lamp output 1 - Short circuit to ground high side
P1383-00 516286 4 Configurable machine lamp output 1 - Short circuit to ground low side
P2557-00 2430 11 Coolant level sensor - Out of range AWL 1587 100
P2559-00 2430 3 Coolant level sensor - Short circuit to battery AWL
P2558-00 2430 4 Coolant level sensor - Short circuit to ground or open circuit AWL
P2557-1C 2430 31 Coolant level sensor - Supply voltage out of range AWL
P0115-13 110 5 Coolant temperature sensor - Open circuit AWL LVL 1
P0116-64 110 2 Coolant temperature sensor - Plausibility error
P0118-00 110 3 Coolant temperature sensor - Short circuit to battery AWL LVL 1
P0117-00 110 4 Coolant temperature sensor - Short circuit to ground AWL LVL 1
P0115-1C 110 31 Coolant temperature sensor - Supply voltage out of range AWL LVL 1
P0335-64 637 2 Crankshaft position - Plausibility error AWL - RSL LVL 2 Check speed sensors for visible defects
P0335-F0 637 14 Crankshaft position sensor - Ground error AWL - RSL LVL 2
P0335-13 637 5 Crankshaft position sensor - Open circuit AWL - RSL LVL 2
P0338-00 637 3 Crankshaft position sensor - Short circuit to battery AWL - RSL LVL 2
P0338-00 637 3 Crankshaft position sensor - Short circuit to battery or open circuit AWL - RSL LVL 2
P0337-00 637 4 Crankshaft position sensor - Short circuit to ground AWL - RSL LVL 2
P0335-1C 637 31 Crankshaft position sensor - Supply voltage out of range AWL - RSL LVL 2
U1013-00 516184 2 Dashboard - Communication error
P12E4-00 1136 0 ECU - Critical overtemperature AWL STOP
P12E5-00 1136 15 ECU - Overtemperature warning AWL - RSL LVL 2
P1239-00 516139 5 Ecu state lamp - Open circuit
P1237-00 516139 3 Ecu state lamp - Short circuit to battery high side
P1360-00 516267 3 Ecu state lamp - Short circuit to battery low side
P1238-00 516139 4 Ecu state lamp - Short circuit to ground high side
P1370-00 516268 4 Ecu state lamp - Short circuit to ground low side
P0666-1C 1136 31 ECU temperature sensor 1 - Supply voltage out of range AWL - RSL LVL 2
P06AB-1C 516140 31 ECU temperature sensor 2 - Supply voltage out of range AWL - RSL LVL 2
P1345-1C 516141 31 ECU temperature sensor 3 - Supply voltage out of range AWL - RSL LVL 2
P1038-00 190 0 Engine - Critical overspeed AWL
P0219-00 190 15 Engine - Overspeed warning
P154F-00 516489 5 Engine CAN on machine connector - Open circuit AWL LVL 1
U1032-00 516355 31 Engine control unit - Communication error to SCR slave control unit MIL Indcmnt
U0033-00 639 5 Engine Control Unit CAN 1 - Open circuit
U0036-00 639 11 Engine Control Unit CAN 1 - Short circuit
U0012-00 625 5 Engine Control Unit CAN 2 - Open circuit AWL LVL 1
U0018-00 625 11 Engine Control Unit CAN 2 - Short circuit MIL Indcmnt
P1016-00 110 0 Engine coolant - Critical overtemperature AWL
P2560-00 111 17 Engine coolant - Level low AW
P1015-00 110 15 Engine coolant - Overtemperature warning AWL
P1032-00 100 1 Engine oil - Critical underpressure AWL - RSL LVL 2
P252F-00 98 15 Engine oil - Level above max
P250F-00 98 17 Engine oil - Level below min
P127A-00 98 11 Engine oil - Level low
P0521-64 100 2 Engine oil - Plausibility error AWL LVL 1
P0524-00 100 17 Engine oil - Underpressure warning 3048 3060 The sensor is working correctly, the measured pressure is lower than a threshold.
P140A-00 516354 0 Engine protection power reduction - Turbocharger protection
P1142-00 5543 13 Exhaust flap - Calibration error MIL Indcmnt
U1017-00 5543 2 Exhaust flap - Communication error MIL Indcmnt
U1016-00 5543 11 Exhaust flap - Communication error detected by smart component MIL Indcmnt
P1144-00 516151 11 Exhaust flap - Control deviation error AWL LVL 2
P1143-00 516153 11 Exhaust flap - Error invalid reference position MIL Indcmnt
P1140-00 516152 11 Exhaust flap - Hardware error MIL Indcmnt
P154B-00 516471 31 Exhaust flap - No sensor position data available MIL Indcmnt
P1141-00 516154 11 Exhaust flap - Overtemperature warning MIL Indcmnt
P1146-00 5543 7 Exhaust flap - Position sensor error MIL Indcmnt
P1145-00 5543 31 Exhaust flap - Supply voltage out of range MIL Indcmnt
P1197-00 516155 13 Exhaust flap 2 - Calibration error MIL Indcmnt
U1022-00 516155 2 Exhaust flap 2 - Communication error MIL Indcmnt
U1021-00 516155 11 Exhaust flap 2 - Communication error detected by smart component MIL Indcmnt
P1199-00 516156 11 Exhaust flap 2 - Control deviation error AWL LVL 2
P1198-00 516158 11 Exhaust flap 2 - Error invalid reference position MIL Indcmnt
P1195-00 516157 11 Exhaust flap 2 - Hardware error MIL Indcmnt
P1563-00 516472 31 Exhaust flap 2 - No sensor position data available MIL Indcmnt
P1196-00 516303 11 Exhaust flap 2 - Overtemperature error MIL Indcmnt
P1201-00 516155 7 Exhaust flap 2 - Position sensor error MIL Indcmnt
P1200-00 516155 31 Exhaust flap 2 - Supply voltage out of range MIL Indcmnt
P1327-00 516300 11 Exhaust flap management 1 - Auto calibration task error MIL Indcmnt
P1328-00 516301 11 Exhaust flap management 1 - Auto learn task error MIL Indcmnt
P1329-00 516302 11 Exhaust flap management 1 - Learnt values lost during normal operation MIL Indcmnt
P132A-00 516159 11 Exhaust flap management 2 - Auto calibration task error MIL Indcmnt
P132B-00 516160 11 Exhaust flap management 2 - Auto learn task error MIL Indcmnt
P132C-00 516161 11 Exhaust flap management 2 - Learnt values lost during normal operation MIL Indcmnt
P1074-00 4360 0 Exhaust gas temperature (upstream SCR) - Critical overtemperature
P1073-00 4360 15 Exhaust gas temperature (upstream SCR) - Overtemperature warning
P2031-13 4360 5 Exhaust gas temperature sensor (upstream SCR) - Open circuit MIL Indcmnt0
P2084-64 4360 2 Exhaust gas temperature sensor (upstream SCR) - Plausibility error MIL Indcmnt
P2033-00 4360 3 Exhaust gas temperature sensor (upstream SCR) - Short circuit to battery MIL Indcmnt0
P2032-00 4360 4 Exhaust gas temperature sensor (upstream SCR) - Short circuit to ground MIL Indcmnt0
P2031-1C 4360 31 Exhaust gas temperature sensor (upstream SCR) - Supply voltage out of range MIL Indcmnt0
P1193-00 94 0 Fuel supply - Critical overpressure
P1031-00 174 0 Fuel supply - Critical overtemperature AWL LVL 1
P1194-00 94 1 Fuel supply - Critical underpressure
P1030-00 174 15 Fuel supply - Overtemperature warningd.
P2542-00 94 3 Fuel supply pressure sensor - Short circuit to battery
P2541-00 94 4 Fuel supply pressure sensor - Short circuit to ground or open circuit
P1339-00 94 31 Fuel supply pressure sensor - Supply voltage out of range
P0180-13 174 5 Fuel temperature sensor - Open circuit AWL LVL 10
P0181-64 174 2 Fuel temperature sensor - Plausibility error
P0183-00 174 3 Fuel temperature sensor - Short circuit to battery AWL
P0182-00 174 4 Fuel temperature sensor - Short circuit to ground AWL
P0180-1C 174 31 Fuel temperature sensor - Supply voltage out of range AWL
U012D-00 516195 2 Generator Set Controller - Communication error
P1248-00 516187 11 Ignition digital input - Out of range
P1347-1C 516187 31 Ignition digital input - Supply voltage out of range
P1191-00 1675 11 Inducement system - Engine restart inhibited (empty AdBlue tank)
P1190-00 5826 0 Inducement system - Locked in severe power or speed reduction (SCR system failure)
P1188-00 5826 15 Inducement system - Power or speed reduction (SCR system failure)
P1189-00 5826 0 Inducement system - Severe power or speed reduction (SCR system failure)
P1187-00 5826 11 Inducement system - Warning (SCR system failure)
P020A-25 651 0 Injector 1 - Current Rise time too long
P020A-23 651 8 Injector 1 - No current rise time measured
P0201-00 651 5 Injector 1 - Open circuit 127 50
P0262-00 651 3 Injector 1 - Short circuit to battery
P0261-00 651 4 Injector 1 - Short circuit to ground
P021D-25 660 0 Injector 10 - Current Rise time too long
P021D-23 660 8 Injector 10 - No current rise time measured
P0210-00 660 5 Injector 10 - Open circuit 127 50
P0289-00 660 3 Injector 10 - Short circuit to battery
P0288-00 660 4 Injector 10 - Short circuit to ground
P021E-25 661 0 Injector 11 - Current Rise time too long
P021E-23 661 8 Injector 11 - No current rise time measured
P0211-00 661 5 Injector 11 - Open circuit 127 50
P0292-00 661 3 Injector 11 - Short circuit to battery
P0291-00 661 4 Injector 11 - Short circuit to ground
P021F-25 662 0 Injector 12 - Current Rise time too long
P021F-23 662 8 Injector 12 - No current rise time measured
P0212-00 662 5 Injector 12 - Open circuit 127 50
P0295-00 662 3 Injector 12 - Short circuit to battery
P0294-00 662 4 Injector 12 - Short circuit to ground
P020B-25 652 0 Injector 2 - Current Rise time too long
P020B-23 652 8 Injector 2 - No current rise time measured
P0202-00 652 5 Injector 2 - Open circuit 127 50
P0265-00 652 3 Injector 2 - Short circuit to battery
P0264-00 652 4 Injector 2 - Short circuit to ground
P020C-25 653 0 Injector 3 - Current Rise time too long
P020C-23 653 8 Injector 3 - No current rise time measured
P0203-00 653 5 Injector 3 - Open circuit 127 50
P0268-00 653 3 Injector 3 - Short circuit to battery
P0267-00 653 4 Injector 3 - Short circuit to ground
P020D-25 654 0 Injector 4 - Current Rise time too long
P020D-23 654 8 Injector 4 - No current rise time measured
P0204-00 654 5 Injector 4 - Open circuit 127 50
P0271-00 654 3 Injector 4 - Short circuit to battery
P0270-00 654 4 Injector 4 - Short circuit to ground
P020E-25 655 0 Injector 5 - Current Rise time too long
P020E-23 655 8 Injector 5 - No current rise time measured
P0205-00 655 5 Injector 5 - Open circuit 127 50
P0274-00 655 3 Injector 5 - Short circuit to battery
P0273-00 655 4 Injector 5 - Short circuit to ground
P020F-25 656 0 Injector 6 - Current Rise time too long
P020F-23 656 8 Injector 6 - No current rise time measured
P0206-00 656 5 Injector 6 - Open circuit 127 50
P0277-00 656 3 Injector 6 - Short circuit to battery
P0276-00 656 4 Injector 6 - Short circuit to ground
P021A-25 657 0 Injector 7 - Current Rise time too long
P021A-23 657 8 Injector 7 - No current rise time measured
P0207-00 657 5 Injector 7 - Open circuit 127 50
P0280-00 657 3 Injector 7 - Short circuit to battery
P0279-00 657 4 Injector 7 - Short circuit to ground
P021B-25 658 0 Injector 8 - Current Rise time too long
P021B-23 658 8 Injector 8 - No current rise time measured
P0208-00 658 5 Injector 8 - Open circuit 127 50
P0283-00 658 3 Injector 8 - Short circuit to battery
P0282-00 658 4 Injector 8 - Short circuit to ground
P021C-25 659 0 Injector 9 - Current Rise time too long
P021C-23 659 8 Injector 9 - No current rise time measured
P0209-00 659 5 Injector 9 - Open circuit 127 50
P0286-00 659 3 Injector 9 - Short circuit to battery
P0285-00 659 4 Injector 9 - Short circuit to ground
P12C0-13 105 5 Intake air temperature sensor - Open circuit
P1131-00 105 2 Intake air temperature sensor - Plausibility error
P12BE-00 105 3 Intake air temperature sensor - Short circuit to battery
P12BF-00 105 4 Intake air temperature sensor - Short circuit to ground
P12C0-1C 105 31 Intake air temperature sensor - Supply voltage out of range
P1014-00 102 0 Intake manifold - Critical overpressure
P1012-00 1636 0 Intake manifold - Critical overtemperature
P140C-00 102 1 Intake manifold - Critical underpressure
P1013-00 102 15 Intake manifold - Overpressure warning
P1011-00 1636 15 Intake manifold - Overtemperature warning
P140B-00 102 17 Intake manifold - Underpressure warning
P0236-64 102 2 Intake manifold pressure sensor - Plausibility error
P0238-00 102 3 Intake manifold pressure sensor - Short circuit to battery
P0237-00 102 4 Intake manifold pressure sensor - Short circuit to ground or open circuit
P0235-1C 102 31 Intake manifold pressure sensor - Supply voltage out of range
P1008-13 1636 5 Intake manifold temperature sensor - Open circuit
P1006-00 1636 3 Intake manifold temperature sensor - Short circuit to battery
P1007-00 1636 4 Intake manifold temperature sensor - Short circuit to ground
P1008-1C 1636 31 Intake manifold temperature sensor - Supply voltage out of range
P1266-00 3340 0 Intercharger downstream pressure sensor - Critical overpressure
P1265-00 3340 15 Intercharger downstream pressure sensor - Overpressure warning
P1550-00 3340 2 Intercharger downstream pressure sensor - Plausibility error
P1551-00 3340 11 Intercharger downstream pressure sensor - Pressure too high
P1552-00 3340 1 Intercharger downstream pressure sensor - Pressure too low
P1262-00 3340 3 Intercharger downstream pressure sensor - Short circuit to battery
P1264-14 3340 4 Intercharger downstream pressure sensor - Short circuit to ground or open circuit
P1264-1C 3340 31 Intercharger downstream pressure sensor - Supply voltage out of range
P1261-00 1174 0 Intercharger downstream temperature sensor - Critical overtemperature
P1259-13 1174 5 Intercharger downstream temperature sensor - Open circuit0
P1260-00 1174 15 Intercharger downstream temperature sensor - Overtemperature warning
P1FD7-00 1174 2 Intercharger downstream temperature sensor - Plausibility error
P1257-00 1174 3 Intercharger downstream temperature sensor - Short circuit to battery0
P1258-00 1174 4 Intercharger downstream temperature sensor - Short circuit to ground0
P1259-1C 1174 31 Intercharger downstream temperature sensor - Supply voltage out of range0
U0141-00 695 11 J1939 (CTL) - Communication error
U1028-00 516196 2 J1939 (Prop3) - Communication error
U0140-00 695 2 Management Computer - Communication error
P137F-00 516282 11 Monitoring System - Injector plausibility error0
P1276-00 516198 11 NH3 sensor - Communication error 1587 50
P1163-00 4380 11 NH3 sensor - Electrical error
P1160-00 4383 2 NH3 sensor - Heater performance error
P1279-00 4383 11 NH3 sensor - Heater supply error
P1280-00 516199 15 NH3 sensor - High NH3 concentration
P1180-00 516200 11 NH3 sensor - Internal memory error
P1162-00 516202 11 NH3 sensor - Module-sensor communication error
P1161-00 516201 11 NH3 sensor - Resistance error
U029E-00 3234 2 NOx sensor (downstream SCR) - Communication error MIL Indcmnt
P220F-00 3232 7 NOx sensor (downstream SCR) - Heater performance error MIL Indcmnt
P131A-00 516203 2 NOx sensor (downstream SCR) - Invalid sensor status MIL Indcmnt
P2298-00 3234 0 NOx sensor (downstream SCR) - Offset error MIL Indcmnt
P229E-13 3234 5 NOx sensor (downstream SCR) - Open circuit MIL Indcmnt
P2A01-64 3235 2 NOx sensor (downstream SCR) - Sensor removed from exhaust line MIL Indcmnt
P1003-00 3234 3 NOx sensor (downstream SCR) - Short circuit MIL Indcmnt
U029D-00 3224 2 NOx sensor (upstream SCR) - Communication error MIL Indcmnt
P220E-00 3222 7 NOx sensor (upstream SCR) - Heater performance error MIL Indcmnt
P130F-00 516204 2 NOx sensor (upstream SCR) - Invalid sensor status MIL Indcmnt
P2297-00 3224 0 NOx sensor (upstream SCR) - Offset error MIL Indcmnt
P2200-13 3224 5 NOx sensor (upstream SCR) - Open circuit MIL Indcmnt
P2A00-64 3225 2 NOx sensor (upstream SCR) - Sensor removed from exhaust line MIL Indcmnt
P1129-00 3224 3 NOx sensor (upstream SCR) - Short circuit MIL Indcmnt
P2416-00 516205 11 NOx sensors - Installation error MIL Indcmnt Check sensors wiring and mounting (inversion of sensors)
P0523-00 100 3 Oil pressure sensor - Short circuit to battery
P0522-00 100 4 Oil pressure sensor - Short circuit to ground or open circuit
P1338-00 100 31 Oil pressure sensor - Supply voltage out of range
U3003-F1 3597 1 Power supply - Critical undervoltage
U3003-16 3597 15 Power supply - Overvoltage warning
U3003-1C 3597 31 Power supply - Supply voltage out of range
U3003-17 3597 17 Power supply - Undervoltage warning Check vehicle electrical system (battery, alternator, wireing, connectors)
P0090-19 5571 6 Pressure control valve - Critical high output current AWL - RSL 2 - CRS
P1218-00 5571 0 Pressure control valve - Critical overcurrent
P1284-00 5571 1 Pressure control valve - Critical undercurrent
P1085-00 516209 15 Pressure control valve - Current remains above the set point
P1084-00 516209 17 Pressure control valve - Current remains below the set point
P0090-2A 5571 11 Pressure control valve - Electrical error AWL - RSL 2 - CRS
P0090-13 5571 5 Pressure control valve - Open circuit AWL - RSL 2 - CRS
P0090-31 516422 11 Pressure control valve - Short circuit load AWL - RSL 2 - CRS
P0092-00 5571 3 Pressure control valve - Short circuit to battery high side AWL - RSL 2 - CRS
P13CA-00 516331 3 Pressure control valve - Short circuit to battery low side AWL - RSL 2 - CRS
P0091-00 5571 4 Pressure control valve - Short circuit to ground high side AWL - RSL 2 - CRS
P13CB-00 516332 4 Pressure control valve - Short circuit to ground low side AWL - RSL 2 - CRS
P2294-19 516215 6 Pressure control valve 2 - Critical high output current AWL - RSL 2 - CRS
P12A9-00 516215 0 Pressure control valve 2 - Critical overcurrent
P12A8-00 516215 1 Pressure control valve 2 - Critical undercurrent
P12A4-00 516216 11 Pressure control valve 2 - Current remains above the set point 6350 1275 No action required
P12A3-00 516217 11 Pressure control valve 2 - Current remains below the set point 6350 1275 No action required
P13DA-00 516337 11 Pressure control valve 2 - Electrical error AWL - RSL 2 - CRS
P2294-13 516215 5 Pressure control valve 2 - Open circuit AWL - RSL 2 - CRS
P2294-31 516215 11 Pressure control valve 2 - Short circuit load AWL - RSL 2 - CRS
P2296-00 516215 3 Pressure control valve 2 - Short circuit to battery high side AWL - RSL 2 - CRS
P13D8-00 516337 3 Pressure control valve 2 - Short circuit to battery low side AWL - RSL 2 - CRS
P2295-00 516215 4 Pressure control valve 2 - Short circuit to ground high side AWL - RSL 2 - CRS
P13D9-00 516337 4 Pressure control valve 2 - Short circuit to ground low side AWL - RSL 2 - CRS
P12A5-00 516220 11 Pressure control valve 2- PWM signal - High limit reached No action required
P12A7-00 516221 11 Pressure control valve 2- PWM signal - Plausibility error 22860 1836
P1176-00 516211 11 Pressure control valve- PWM signal - High limit reached No action required
P12DB-00 516212 11 Pressure control valve- PWM signal - Plausibility error 22860 1836 No action required
U1012-00 900 2 Retarder - Driveline - Communication error
U010E-00 3360 2 SCR slave control unit - Communication error MIL Indcmnt - -
P154A-00 516487 0 SCR slave control unit - Detection of an error on SCR slave
P13E1-00 516341 0 SCR slave control unit - Emission relevant error MIL Indcmnt
P1273-00 516230 11 SCR system - Defrosting actuator error (AdBlue) MIL Indcmnt 6350 1000 Read error codes, pay attention to other system errors
P1274-00 516232 11 SCR system - Defrosting sensor error (AdBlue) MIL Indcmnt 6350 1000
P1178-00 516233 11 SCR system - Feedback control reached max saturation 1270 20 No action required
P1179-00 516234 11 SCR system - Feedback control reached min saturation 1270 20 No action required
P13FF-00 516367 2 SCR system - Inverted Air Pressure and Adblue Pressure at the Adblue Pump MIL Indcmnt 2540 40
P0420-00 4364 17 SCR system - Low conversion efficiency 1524 600 No action required
P1126-00 516229 11 SCR system - SCR air valve defect MIL Indcmnt
P1125-00 516235 11 SCR system - Ventilation error (AdBlue)
P1136-00 4364 1 SCR system - Very low conversion efficiency MIL Indcmnt
P1122-00 516236 11 SCR system(AdBlue injector) - AdBlue injection path blocked MIL Indcmnt
P1123-00 516237 11 SCR system(AdBlue injector) - Air path blocked MIL Indcmnt
P204B-64 4334 2 SCR system(AdBlue pressure sensor) - Plausibility error
P204D-00 4334 3 SCR system(AdBlue pressure sensor) - Short circuit to battery
P204C-00 4334 4 SCR system(AdBlue pressure sensor) - Short circuit to ground or open circuit
P1127-00 4334 17 SCR system(AdBlue pressure) - Pressure too low
P133E-00 4334 11 SCR system(AdBlue pressure) - Supply voltage out of range
P05EE-19 5435 6 SCR system(AdBlue pump) - Critical high output current MIL Indcmnt
P05EE-2A 5435 11 SCR system(AdBlue pump) - Electrical error MIL Indcmnt
P05EE-00 5435 5 SCR system(AdBlue pump) - Open circuit MIL Indcmnt
P1121-00 5485 2 SCR system(AdBlue pump) - Out of service MIL Indcmnt
P1059-00 516293 11 SCR system(AdBlue pump) - Short circuit load MIL Indcmnt
P05F0-00 5435 3 SCR system(AdBlue pump) - Short circuit to battery high side MIL Indcmnt
P1390-00 516294 3 SCR system(AdBlue pump) - Short circuit to battery low side MIL Indcmnt
P05EF-00 5435 4 SCR system(AdBlue pump) - Short circuit to ground high side MIL Indcmnt
P1391-00 516295 4 SCR system(AdBlue pump) - Short circuit to ground low side MIL Indcmnt
P2042-13 4337 5 SCR system(AdBlue temperature sensor) - Open circuit0
P2043-64 4337 2 SCR system(AdBlue temperature sensor) - Plausibility error
P2045-00 4337 3 SCR system(AdBlue temperature sensor) - Short circuit to battery
P2044-00 4337 4 SCR system(AdBlue temperature sensor) - Short circuit to ground
P1337-00 4337 31 SCR system(AdBlue temperature sensor) - Supply voltage out of range
P24FF-00 4337 11 SCR system(AdBlue temperature) - Adblue temperature too high in operation MIL Indcmnt
P1166-00 4337 0 SCR system(AdBlue temperature) - Critical overtemperature
P1058-00 4337 15 SCR system(AdBlue temperature) - Overtemperature warning
P1119-00 4335 2 SCR system(air pressure sensor) - Plausibility error MIL Indcmnt
P2040-00 4335 3 SCR system(air pressure sensor) - Short circuit to battery MIL Indcmnt
P2039-00 4335 4 SCR system(air pressure sensor) - Short circuit to ground or open circuit MIL Indcmnt
P2037-1C 4335 31 SCR system(air pressure sensor) - Supply voltage out of range MIL Indcmnt
P1124-00 4335 11 SCR system(air pressure) - Pressure too low MIL Indcmnt
P2059-19 5796 6 SCR system(air pump) - Critical high output current MIL Indcmnrt
P2059-2A 5796 11 SCR system(air pump) - Electrical error MIL Indcmnt
P2059-00 5796 5 SCR system(air pump) - Open circuit MIL Indcmnt
P1120-00 5796 2 SCR system(air pump) - Out of service MIL Indcmnt
P2059-31 516423 11 SCR system(air pump) - Short circuit load MIL Indcmnt
P2061-00 5796 3 SCR system(air pump) - Short circuit to battery high side MIL Indcmnt
P138E-00 516291 3 SCR system(air pump) - Short circuit to battery low side MIL Indcmnt
P2060-00 5796 4 SCR system(air pump) - Short circuit to ground high side MIL Indcmnt
P138F-00 516292 4 SCR system(air pump) - Short circuit to ground low side MIL Indcmnt
P1565-00 516473 6 SCR system(air switch valve) - Critical high output current MIL Indcmnt
P1392-00 516238 11 SCR system(air switch valve) - Electrical error MIL Indcmnt
P1062-00 516238 5 SCR system(air switch valve) - Open circuit MIL Indcmnt
P1060-00 516238 3 SCR system(air switch valve) - Short circuit to battery high side MIL Indcmnt
P1393-00 516296 3 SCR system(air switch valve) - Short circuit to battery low side MIL Indcmnt
P1061-00 516238 4 SCR system(air switch valve) - Short circuit to ground high side MIL Indcmnt
P1394-00 516297 4 SCR system(air switch valve) - Short circuit to ground low side MIL Indcmnt
P1251-00 516239 11 Slave digital input - Out of range MIL Indcmnt0
P1186-1C 516239 31 Slave digital input - Supply voltage out of range MIL Indcmnt0
P1554-00 516426 6 Smart sensor supply relay - Critical high output current MIL Indcmnt
P137D-00 516280 11 Smart sensor supply relay - Electrical error MIL Indcmnt
P1139-00 516245 5 Smart sensor supply relay - Open circuit MIL Indcmnt
P1137-00 516245 3 Smart sensor supply relay - Short circuit to battery high side MIL Indcmnt
P137B-00 516278 3 Smart sensor supply relay - Short circuit to battery low side MIL Indcmnt
P1138-00 516245 4 Smart sensor supply relay - Short circuit to ground high side MIL Indcmnt
P137C-00 516279 4 Smart sensor supply relay - Short circuit to ground low side MIL Indcmnt
P0615-19 677 6 Starter - Critical high output current AWL
P0615-2C 677 11 Starter - Electrical error AWL
P0615-98 516342 31 Starter - Locked due to overtemperature
P0615-13 677 5 Starter - Open circuit
P0617-00 677 3 Starter - Short circuit to battery high side
P1379-00 516276 3 Starter - Short circuit to battery low side
P0618-00 677 4 Starter - Short circuit to ground high side
P137A-00 516277 4 Starter - Short circuit to ground low side
P1249-00 516247 11 Starter digital input - Out of range
P1324-00 516424 11 Starter digital input - Starter inhibition due to short circuit
P1181-1C 516247 31 Starter digital input - Supply voltage out of range
U019A-00 1620 2 Tachograph - Communication error
U0114-00 1845 2 Transmission - Communication error
P0001-19 1076 6 Volume control valve - Critical high output current AWL - RSL 2 - CRS
P1220-00 1076 0 Volume control valve - Critical overcurrent 1270 255
P12DF-00 1076 1 Volume control valve - Critical undercurrent 1270 255
P1083-00 516251 11 Volume control valve - Current remains above the set point
P1082-00 516252 11 Volume control valve - Current remains below the set point
P0001-2A 516330 11 Volume control valve - Electrical error AWL - RSL 2 - CRS
P0001-13 1076 5 Volume control valve - Open circuit AWL - RSL 2 - CRS
P0001-31 1076 11 Volume control valve - Short circuit load AWL - RSL 2 - CRS
P0004-00 1076 3 Volume control valve - Short circuit to battery high side AWL - RSL 2
P13C8-00 516328 3 Volume control valve - Short circuit to battery low side AWL - RSL 2
P0003-00 1076 4 Volume control valve - Short circuit to ground high side AWL - RSL 2
P13C9-00 516329 4 Volume control valve - Short circuit to ground low side AWL - RSL 2
P129D-19 516255 6 Volume control valve 2 - Critical high output current AWL - RSL 2
P12E0-00 516255 0 Volume control valve 2 - Critical overcurrent 1270 255
P12E1-00 516255 1 Volume control valve 2 - Critical undercurrent 1270 255
P12A1-00 516256 11 Volume control valve 2 - Current remains above the set point
P12A0-00 516257 11 Volume control valve 2 - Current remains below the set point
P13D5-00 516336 11 Volume control valve 2 - Electrical error AWL - RSL 2
P129D-13 516255 5 Volume control valve 2 - Open circuit AWL - RSL 2
P129E-00 516255 11 Volume control valve 2 - Short circuit load AWL - RSL 2
P129B-00 516255 3 Volume control valve 2 - Short circuit to battery high side AWL - RSL 2
P13D6-00 516336 3 Volume control valve 2 - Short circuit to battery low side AWL - RSL 2
P129C-00 516255 4 Volume control valve 2 - Short circuit to ground high side AWL - RSL 2
P13D7-00 516336 4 Volume control valve 2 - Short circuit to ground low side AWL - RSL 2
P12A2-00 516258 11 Volume control valve 2- PWM signal - High limit reached
P12A6-00 516259 11 Volume control valve 2- PWM signal - Plausibility error 22860 1836
P1177-00 516253 11 Volume control valve- PWM signal - High limit reached
P12DA-00 516254 11 Volume control valve- PWM signal - Plausibility error 22860 1836
P0243-19 5386 6 Wastegate valve - Critical high output current
P0243-2A 5386 11 Wastegate valve - Electrical error
P0243-13 5386 5 Wastegate valve - Open circuit
P0243-31 516318 11 Wastegate valve - Short circuit load
P0246-00 5386 3 Wastegate valve - Short circuit to battery high side
P135D-00 516266 3 Wastegate valve - Short circuit to battery low side
P0245-00 5386 4 Wastegate valve - Short circuit to ground high side
P135E-00 516266 4 Wastegate valve - Short circuit to ground low side
P2264-13 97 5 Water in fuel sensor - Open circuit
P2265-00 97 11 Water in fuel sensor - Out of range
P2267-00 97 3 Water in fuel sensor - Short circuit to battery
P2266-00 97 4 Water in fuel sensor - Short circuit to ground
P2264-1C 97 31 Water in fuel sensor - Supply voltage out of range
P1275-00 97 0 Water in fuel sensor - Water in fuel detected Drain water from fuel circuit pre filter